Specifications
Detection Method | Bichromatic Photometer |
---|---|
No. of Reactions | 100 Tests |
Quantity | 1 Ea. |
Storage Requirements | 2°C to 8°C |
Includes: Reagent A, Reagent B, Reagent C, Calibrators
Catalog Number | Mfr. No. | Target Molecule | Price | Quantity & Availability | |||||
---|---|---|---|---|---|---|---|---|---|
Catalog Number | Mfr. No. | Target Molecule | Price | Quantity & Availability | |||||
MP7KTAK2000
|
MP Biomedicals™
07KTAK2000 |
Alkenal |
Each for $949.00
|
|
|||||
MP7KTFA2000
|
MP Biomedicals™
07KTFA2000 |
Free Fatty Acid |
Each for $676.00
|
|
|||||
MP7KTMA2000
|
MP Biomedicals™
07KTMA2000 |
Malonaldehyde |
Each for $946.00
|
|
|||||
MP7KTPF2000
|
MP Biomedicals™
07KTPF2000 |
Percent Fat |
Each for $845.00
|
|
|||||
MP7KTPR2000
|
MP Biomedicals™
07KTPR2000 |
Peroxide |
Each for $849.72
|
|
|||||
MP7KTTG2000
|
MP Biomedicals™
07KTTG2000 |
Total Glycerin |
Each for $830.00
|
|
|||||
Description
MP Biomedicals' Test Kits contain all reagents and calibrators necessary to run samples. A control is also included in each Test Kit. Each kit will allow for testing of approximately 100 samples. Sample dilution will likely be required for appropriate analysis.
- Choose from 6 different kits
- For use with SafTest instrument and consumable platforms
- Results in as little as 30 minutes
- Detection method: Bichromatic Photometer
- Test Kits contain all reagents and calibrators necessary to run samples.
- A control is also included in each Test Kit.
- Each kit will allow for testing of approximately 100 samples.
- Sample dilution will likely be required for appropriate analysis.
- Alkenal Test Kit
- Research Area: Lipid degradation and oxidation
- Contains all reagents, calibrators
- Free Fatty Acid Test Kit
- Research Area: Lipid degradation and oxidation
- Components: Reagent A, Reagent B, Calibrators, Control Analyte(s)
- Required: SafTest Instrument Platform, Consumables Platform and Dispenser Set
- Quantitation Range: 0.1 - 2.01% free fatty acid
- Malonaldehyde Test Kit
- Research Area: Lipid degradation and oxidation
- Components: Reagent A, Reagent B, Calibrators, Control
- Materials Required: SafTest Instrument Platform, Consumables Platform and Dispenser Set
- Quantitation Range: 0.00 to 0.32 mg/kg of sample
- Percent Fat Test Kit
- Research Area: Lipid degradation and oxidation
- Components: Reagent A, Reagent B, Calibrators, Control Analytes(s)
- Material Required: SafTest Instrument Platform
- Quantitation Range: 0.06 to 0
- Peroxide Test Kit
- Research Area: Lipid degradation and oxidation
- Components: Reagent A, Reagent B, Reagent C, Calibrators, Control Analyte(s)
- Materials Required: SafTest Instrument Platform, Consumables Platform and Dispenser Set
- Quantitation Range: 0.00 to 0.200 MEQ/kg of sample
- Total Glycerin Test Kit
- Research Area: Biodiesel
- Components: Reagent A, Reagent B, Calibrators, Control
- Materials Required: SafTest Instrument Platform, Consumables Platform and Dispenser Set
- Quantitation Range: 0.008 to 0.06% of sample
Specifications
Bichromatic Photometer | |
100 Tests | |
1 Ea. | |
2°C to 8°C |
Unless specified otherwise, for research or further manufacturing use only, not for direct human use.