Benchtop Titrators
Benchtop Titrators
- (3)
- (3)
- (4)
- (2)
- (1)
- (4)
- (2)
- (2)
- (3)
- (2)
- (1)
- (4)
- (1)
- (2)
- (3)
- (1)
- (5)
- (4)
- (4)
- (1)
- (5)
- (1)
- (1)
- (4)
- (1)
- (2)
- (2)
- (5)
- (10)
- (2)
- (1)
- (7)
Filtered Search Results
Mettler Toledo™ G10S Compact Potentiometric Titrator
Ideal for fast and precise potentiometric titration with very simple operation. Mettler Toledo G10S Compact Potentiometric Titrator has an easy-to-use interface and space saving design which makes it an ideal choice for daily routine analysis.
Thermo Scientific™ Orion Star T940 All-in-One Titrator and Kits
Benefit from the integration of our core electrochemistry technology with a state-of-the-art dispensing system to create an automated all-in-one titrator, a modern, simplified automated system designed to help make performing titrations easier, more reliable and more reproducible than manual titrations.
Titration Technique | Equivalence point or preset endpoint |
---|---|
Memory | Non-volatile memory preserves data logs and settings |
Advanced ISE Functions | Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette |
Resolution (pH) | 0.001, 0.01, 0.1 (user selectable) |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
Data Management Details | Data log export as CSV or PDF file, short or long format |
Display Type | 5.7” color capacitive touchscreen, 640 x 480 resolution |
Functions Available | Sample titration, titrant standardization, calibration and direct measure |
Resolution (mV) | 0.1 mV |
Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
Temperature Probe Calibration | Optional 1 point offset calibration |
Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
Probe Type | pH electrode, redox electrode or ion selective electrode (ISE); reference half-cell electrode; ATC temperature probe; stirrer probe |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading, whichever is greater |
Titrant Determination | Standardization titration or manual concentration input |
Warranty | 1 year replacement warranty |
Calibration Points (ISE) | 1 to 5 |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm |
Temperature Selection | Manual or automatic |
Precision | 0.5% RSD, dependent on environment and handling conditions |
Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes, adjustable |
Range (mV) | -2000.0 to +2000.0 mV |
Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
Titration Process Control | Routine, quick, careful or user defined |
Time and Date | Yes, with nonvolatile battery backup |
Updateable Firmware | Yes, using USB flash drive |
Range (pH) | -2 to 20 |
For Use With (Application) | Acid-base titrations, redox titrations, ion concentration titrations |
Titration Types | Direct or back titration |
Channels | 1 |
Accuracy (pH) | ±0.002pH |
Range (ISE) | 0.0001 to 19990 |
Titration Setup Wizard | Yes, using Start a New Titration workflow |
Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
Inputs | BNC (pH, redox or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.2 °C |
Equivalence Points | 1 to 2 |
Electrical Requirements | 100-240V, 50/60 Hz |
Temperature (English) Operating | 41°F to 104°F |
Preset Endpoints | 1 to 3 |
Material | ABS Plastic |
Calibration | pH, mV, ion concentration (ISE) and temperature |
Calibration Points | 1 point relative mV (RmV) mode |
Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
Type | Acid/base, redox and ion titrator |
IP Rating | IP-51 |
Model | Orion Star T940 |
Sample ID | Auto-incremental, manual or off |
Resolution (Temperature) | 0.1 °C |
Temperature Range (Metric) | -5.0°C to +100.0°C |
Temperature (Metric) Operating | 5°C to 40°C |
Blank Options | Fixed value or variable value using titration |
Mettler Toledo™ G20S Compact Potentiometric Titrator
Ideal for fast and precise potentiometric titration with very simple operation. Mettler Toledo G20S Compact Potentiometric Titrator has an easy-to-use interface and space saving design which makes it an ideal choice for daily routine analysis.
Sample Size | 120 (per series) |
---|---|
Type | Potentiometric Titrator |
Display Type | VGA 5.7 in. color TFT, 640 x 480 pixel |
Depth (Metric) | 33.3 cm |
Detection Range | 0 to 2000mV/0 to 200μA (Ipol/Upol), -20° to 130°C (PT1000 Temperature Sensor) |
Model | G20S |
Certifications/Compliance | CE, ISO 9001, ISO 14001 |
Range (mV) | ±2000 mV |
Width (Metric) | 21 cm |
Resolution | 0.1mV (Potentiometric Sensor Input), 0.1mV/0.1μA (Polarized Sensor Input), 0.1°C (PT1000 Temperature Sensor), 1μL (Burette) |
METTLER TOLEDO™ EasyPlus Easy Cl Titrator
Used to automate and speed up simple precipitation titrations. EasyPlus Easy Cl Titrator for the determination of chloride content in food industry, salt content of waste and drinking water, sulfide or mercaptan content of oils and lubricants and silver content of solutions and dissolved metals.
METTLER TOLEDO™ EasyPlus Easy pH Titrator
Used to automate and speed up simple acid/base titrations. The EasyPlus Easy pH Titrator is ideal for the determining the acidity content of beverages, alkalinity of cleaning reagents and chemicals, free fatty acid content of cooking oils, and alkalinity (m-value) and acidity (p-value) of water.
Thermo Scientific™ Orion Star T910 pH Titrator and Kits
Benefit from the integration of our core electrochemistry technology with a state-of-the-art dispensing system to create an automated pH titrator, a modern, simplified automated system designed to help make performing titrations easier, more reliable and more reproducible than manual titrations.
Titration Technique | Equivalence point or preset endpoint |
---|---|
Memory | Non-volatile memory preserves data logs and settings |
Resolution (pH) | 0.001, 0.01, 0.1 (user selectable) |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
Data Management Details | Data log export as CSV or PDF file, short or long format |
Display Type | 5.7” color capacitive touchscreen, 640 x 480 resolution |
Functions Available | Sample titration, titrant standardization, calibration and direct measure |
Resolution (mV) | 0.1 mV |
Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
Temperature Probe Calibration | Optional 1 point offset calibration |
Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
Probe Type | pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe |
Accuracy (mV) | ±0.2 mV |
Titrant Determination | Standardization titration or manual concentration input |
Warranty | 1 year replacement warranty |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm |
Temperature Selection | Manual or automatic |
Precision | 0.5% RSD, dependent on environment and handling conditions |
Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes, adjustable |
Range (mV) | -2000.0 to +2000.0 mV |
Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
Titration Process Control | Routine, quick, careful or user defined |
Time and Date | Yes, with nonvolatile battery backup |
Updateable Firmware | Yes, using USB flash drive |
Range (pH) | -2 to 20 |
For Use With (Application) | Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN) |
Titration Types | Direct or back titration |
Channels | 1 |
Accuracy (pH) | ±0.002pH |
Titration Setup Wizard | Yes, using Start a New Titration workflow |
Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
Inputs | BNC (pH electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.2 °C |
Equivalence Points | 1 to 2 |
Electrical Requirements | 100-240V, 50/60 Hz |
Temperature (English) Operating | 41°F to 104°F |
Preset Endpoints | 1 to 3 |
Material | ABS Plastic |
Calibration | pH and temperature |
Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
Type | Acid/base titrator |
IP Rating | IP-51 |
Model | Orion Star T910 |
Sample ID | Auto-incremental, manual or off |
Resolution (Temperature) | 0.1 °C |
Temperature Range (Metric) | -5.0°C to +100.0°C |
Temperature (Metric) Operating | 5°C to 40°C |
Blank Options | Fixed value or variable value using titration |
Mettler Toledo™ C10S Compact Coulometric KF Titrators
Ideal for fast and precise water content determination with very simple operation. Mettler Toledo C10S Coulometric KF Titrators can analyze samples with water content between 1ppm and 5% in single measurements or as sample series with statistics.
Sample Size | 120 (per series) |
---|---|
Type | Coulometric KF Titrator |
Display Type | VGA 5.7 in. color TFT, 640 x 480 pixel |
Depth (Metric) | 34 cm |
Detection Range | 0 to 24μA (Polarization Current Range) |
Temperature Range (Metric) Ambient | 5°C to 40°C |
Certifications/Compliance | CE, ISO 9001, ISO 14001 |
Range (mV) | -2000 to +2000 mV |
For Use With (Application) | Liquid and gaseous samples; Resources and method database |
Width (Metric) | 21 cm |
Resolution | 0.1mV/2mV; 0.1μA/1μA; 0.1μg |
METTLER TOLEDO™ EasyPlus Easy Pro Titrator
Combines acid/base equivalence point, pH endpoint, and precipitation/redox indicative titrations on one instrument. Simple titrations of juice, wine, free fatty acids in food, chloride in food, and sulfides in oils, and more are all easily performed with the EasyPro titrator.
Mettler Toledo™ C20S Compact Coulometric KF Titrators
Ideal for fast and precise water content determination with very simple operation. Mettler Toledo C20S Coulometric KF Titrators can analyze samples with water content between 1ppm and 5% in single measurements or as sample series with statistics.
Sample Size | 120 (per series) |
---|---|
Type | Coulometric KF Titrator |
Display Type | VGA 5.7 in. color TFT, 640 x 480 pixel |
Depth (Metric) | 34 cm |
Detection Range | 0 to 24μA (Polarization Current Range) |
Temperature Range (Metric) Ambient | 5°C to 40°C |
Certifications/Compliance | CE, ISO 9001, ISO 14001 |
Range (mV) | -2000 to +2000 mV |
For Use With (Application) | Liquid and gaseous samples; Resources and method database |
Width (Metric) | 21 cm |
Resolution | 0.1mV/2mV; 0.1μA/1μA; 0.1μg |
METTLER TOLEDO™ EasyPlus Easy KFV Titrator
Simplifies water content determination and is ideal for routine volumetric Karl Fischer titrations of food, chemical products and various other sample types. The Easy KFV quickly and easily determines water content from 100 ppm up to 100% in just a few minutes.
METTLER TOLEDO™ EasyPlus Easy Dose Dosing Device
A sample preparation device designed to perform precise, accurate, error-free, and fully automated, liquid handling tasks down to 10 μL. Ensure your sample preparation tasks are error free and reduce tedious, time-consuming, and variable manual operations with Easy Dose.
Thermo Scientific™ Orion Star T920 Redox Titrator and Kit
Benefit from the integration of our core electrochemistry technology with a state-of-the-art dispensing system to create an automated redox titrator, a modern, simplified automated system designed to help make performing titrations easier, more reliable and more reproducible than manual titrations.
Titration Technique | Equivalence point or preset endpoint |
---|---|
Memory | Non-volatile memory preserves data logs and settings |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
Data Management Details | Data log export as CSV or PDF file, short or long format |
Display Type | 5.7” color capacitive touchscreen, 640 x 480 resolution |
Functions Available | Sample titration, titrant standardization, calibration and direct measure |
Resolution (mV) | 0.1 mV |
Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
Temperature Probe Calibration | Optional 1 point offset calibration |
Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
Probe Type | Redox/ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe |
Accuracy (mV) | ±0.2 mV |
Titrant Determination | Standardization titration or manual concentration input |
Warranty | 1 year replacement warranty |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm |
Temperature Selection | Manual or automatic |
Precision | 0.5% RSD, dependent on environment and handling conditions |
Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
Backlight Option | Yes, adjustable |
Range (mV) | -2000.0 to +2000.0 mV |
Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
Titration Process Control | Routine, quick, careful or user defined |
Time and Date | Yes, with nonvolatile battery backup |
Updateable Firmware | Yes, using USB flash drive |
For Use With (Application) | Redox titrations including sulfite/SO2 and reducing sugar in juice and wine, ascorbic acid (vitamin C) and peroxide value in food products, dissolved oxygen in wastewater by Winkler titration and organic matter in soil |
Titration Types | Direct or back titration |
Channels | 1 |
Titration Setup Wizard | Yes, using Start a New Titration workflow |
Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
Inputs | BNC (redox/ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.2 °C |
Equivalence Points | 1 to 2 |
Electrical Requirements | 100-240V, 50/60 Hz |
Temperature (English) Operating | 41°F to 104°F |
Preset Endpoints | 1 to 3 |
Material | ABS Plastic |
Calibration | mV and temperature |
Calibration Points | 1 point relative mV (RmV) mode |
Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
Type | Redox titrator |
IP Rating | IP-51 |
Model | Orion Star T920 |
Sample ID | Auto-incremental, manual or off |
Resolution (Temperature) | 0.1 °C |
Temperature Range (Metric) | -5.0°C to +100.0°C |
Temperature (Metric) Operating | 5°C to 40°C |
Blank Options | Fixed value or variable value using titration |
METTLER TOLEDO™ Easy Na Sodium Analyzer
Simplifies the determination of sodium in food products using the standard addition technique. Easy Na Sodium Analyzer is simple to operate, fast, and accurate. Upgrade from manual titration to automation and increase the speed and accuracy of your sodium content analysis.
Thermo Scientific™ Orion Star T930 Ion Titrator and Kits
Benefit from the integration of our core electrochemistry technology with a state-of-the-art dispensing system to create an automated redox titrator, a modern, simplified automated system designed to help make performing titrations easier, more reliable and more reproducible than manual titrations.
Titration Technique | Equivalence point or preset endpoint |
---|---|
Memory | Non-volatile memory preserves data logs and settings |
Advanced ISE Functions | Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
Data Management Details | Data log export as CSV or PDF file, short or long format |
Display Type | 5.7” color capacitive touchscreen, 640 x 480 resolution |
Functions Available | Sample titration, titrant standardization, calibration and direct measure |
Resolution (mV) | 0.1 mV |
Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
Temperature Probe Calibration | Optional 1 point offset calibration |
Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
Probe Type | Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading, whichever is greater |
Titrant Determination | Standardization titration or manual concentration input |
Warranty | 1 year replacement warranty |
Calibration Points (ISE) | 1 to 5 |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm |
Temperature Selection | Manual or automatic |
Precision | 0.5% RSD, dependent on environment and handling conditions |
Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
Backlight Option | Yes, adjustable |
Range (mV) | -2000.0 to +2000.0 mV |
Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
Titration Process Control | Routine, quick, careful or user defined |
Time and Date | Yes, with nonvolatile battery backup |
Updateable Firmware | Yes, using USB flash drive |
Titration Types | Direct or back titration |
Channels | 1 |
Range (ISE) | 0.0001 to 19990 |
Titration Setup Wizard | Yes, using Start a New Titration workflow |
Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
Inputs | BNC (ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.2 °C |
Equivalence Points | 1 to 2 |
Electrical Requirements | 100-240V, 50/60 Hz |
Temperature (English) Operating | 41°F to 104°F |
Preset Endpoints | 1 to 3 |
Material | ABS Plastic |
Calibration | Ion concentration (ISE) and temperature |
Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
Type | Ion titrator |
IP Rating | IP-51 |
Model | Orion Star T930 |
Sample ID | Auto-incremental, manual or off |
Resolution (Temperature) | 0.1 °C |
Temperature Range (Metric) | -5.0°C to +100.0°C |
Temperature (Metric) Operating | 5°C to 40°C |
Blank Options | Fixed value or variable value using titration |
METTLER TOLEDO™ EasyPlus Easy Ox Titrator
Everything you need for automated redox titrations, including SO2 determination in wine, reducing sugars, peroxide values, vitamin C content, and much more.