Test
Used for traditional general purpose applications, where a non-polar column is required.
Max. Temperature | -60°C to +300°C (isothermal or programmed) |
---|---|
Type | Capillary GC |
Packing Material | Poly(dimethyl siloxane) |
Diameter (Metric) Inner | 0.53 mm |
Polarity | Non-Polar |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 1.5 μm |
USP Type | G1, G2, G9 |
Product Line | SPB |
Use Thermo Scientific™ TracePLOT TG-BOND Alumina GC Columns for linear and quantitative analysis of polar unsaturated hydrocarbons.
Max. Temperature | Up to 200°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Alumina |
For Use With (Application) | Polar Unsaturated Hydrocarbons Analysis,GC for Unsaturated Hydrocarbon Isomers,Linear and Quantitative Analysis of Polar Unsaturated Hydrocarbons |
Choose these colums that feature a popular GCMS phase for many applications.
Stationary Phase | Trace™ TR-5 MS |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Separate ethane, ethylene and acetylene consistently with the intermediate polarity PLOT column with essentially no particle release.
Max. Temperature | Up to 250°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Q+ |
Polarity | Mid-Polar |
For Use With (Application) | GC for the Separation of Ethane, Ethylene, and Acetylene to Baseline |
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
Max. Temperature | 340/360°C |
---|---|
Stationary Phase | TraceGOLD™ TG-XLBMS |
Polarity | Low-Polar |
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |
Greater stability and inertness at elevated temperatures and when working with highly active compounds.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MT |
Polarity | Low-Polar |
USP Type | G27, G36 |
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
Max. Temperature | 330/360°C |
---|---|
Polarity | Mid-Polar |
USP Type | G42 |
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
An economical metal column should be used for less demanding applications where the inertness of glass is not required.
An economical metal column should be used for less demanding applications where the inertness of glass is not required.
Achieve consistent, reproducible separation of CO2, methane and 02/N2/CO with the non-polar PLOT column with essentially no particle release.
Max. Temperature | Up to 300/320°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Q |
Polarity | Non-Polar |
Utilizes a chemically altered tubing surface to reduce peak tailing and eliminates the need for column priming when analysing amines and other basic compounds.
Max. Temperature | 220°C |
---|---|
Stationary Phase | TraceGOLD™ TG-35 MS Amine |
Polarity | Mid-Polar |
For Use With (Application) | GC/MS Amines Including Alkylamines, Diamines, Triamines and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |
Use Thermo Scientific™ TracePLOT™ TG-BOND Alumina GC Columns for linear and quantitative analysis of polar unsaturated hydrocarbons.
Stationary Phase | TracePLOT™ TG-BOND Alumina |
---|